![]() ![]() ![]() Select the Maintenance plan scheduling parameters tab. ![]() Kindly update the maintenance plan with relevant details like Maintenance Plan Description, Maintenance Item Description, Order Type, Planner Group, Work Center, Task list and Priority. Here the scenario has only one cycle set sequence.Ĭycle set sequence, Scheduling period, Start date will be populated in the multiple counter maintenance plan (IP43) after activating the “Configure Special Functions for Maintenance Planning” in SPRO. Select the Maintenance plan category and Cycle set ( Cycle set not mandatory)Ĭycle sets will be copied to the maintenance planĬycle set sequence needs to be filled and same has to be linked to maintenance item. Also cycle sets can be complied directly in multiple counter plan itself.Ĭycle sets needs to be created based on business requirement. It defines the period of time between two maintenance tasks. Two documents are posted for this measuring point / counter.Ĭycle sets are used as a copy model for the creation of multiple counter plan. On save, first measurement document created for measuring point / counter. Record the current running hours reading of the Pump using measuring documents (IK11), this is required to schedule the plan. On save, measuring point / counter is created. This needs to be filled, maintenance intervals are calculated based on this data. Enter a logical value for the first counter reading.Īnnual Estimate – Estimated hours the equipment can run in a year. MeasPosition – This describes the position of the measuring point / counter with respect to the Technical Object.Ĭounter Overflow reading – The first counter reading that the counter cannot display. In the measuring counter, you need to maintain below fields To make the measurement point as a Counter, you need to check “MeasPoint is counter”Įnsure characteristics you want to assign to measuring point / counter were created To record the running hours we need to create measuring point / counter.Ĭreate the Measuring point for Equipment, enter the object type IEQ We are going to record the running hours of the Pump. I have created PUMP as Equipment for explaining this scenario. Measuring Point/Counter assigned to Equipment.Characteristics for measuring point / counter.This means that you can create a multiple counter plan without maintenance strategy.īelow are the list of basic Master data required to process Multiple Counter Plan. This type of maintenance planning is not based on a maintenance strategy. In this document we will be going through various steps involved to develop Multiple counter plan.Ī multiple counter plan is used in counter based maintenance. ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |